| Introduction to Electric Power Systems | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| COURSE DESCRIPTION | |||||||||||||||||||||||||||
Course Introduction:
Power systems are subjected to faults, which occur mostly as a result of insulation failure, overloading and more serious short circuit faults. When a fault occurs, the normal functioning of the system gets disturbed. The high current resulting from a fault can stress the electrical conductors and connected equipment thermally and electro-dynamically. Arcs at the fault point can cause dangerous or even fatal burn injuries to operating and maintenance workers in the vicinity. Faults involving one phase and ground give rise to high 'touch' and 'step' voltages posing danger of electrocution to personnel working nearby. It is therefore necessary to detect and clear any fault quickly.
The first device used in early electrical systems was the fuse, which acted both as the sensor and the interrupting device. With larger systems, separate devices became necessary to sense and interrupt fault currents. In the beginning these functions were combined in a single assembly; a circuit breaker with in-built releases. This practice is still prevalent in low voltage systems. In both high systems and low voltage systems of higher capacities, the sensing is done by more sophisticated devices called relays. Relays were initially electromechanical devices but static relays and more recently digital relays have become the norm.
With more complex systems, it is necessary to detect the point of fault precisely and trip only those sections affected by the fault while the rest of the system can continue to function normally. In the event of the nearest circuit breaker failing to operate, the next breaker in the upstream (feeding) side has to be tripped as a 'back up' measure.
Another requirement is to minimize the time for which a fault remains in the circuit; this is necessary to reduce equipment damage and the danger to operating personnel. These requirements necessitate different forms of relaying apart from the simple current sensing relays. Equipment such as generators, transformers and motors also need special forms of protection characterized by their design and operating principles. This course will explain all of these points in detail and provide you with the skills and knowledge necessary to calculate fault currents, select relays and associated instrument transformers appropriate to each typical system or equipment. You will also learn how to adjust the setting of the relays so that the relays closest to the fault will operate and clear the fault faster than the backup devices.
Course Objectives:
This training course will be valuable to participants who either work in the power industry or deal with it externally. Those who need a fundamental understanding of the Power systems, or how it operates will find this course applicable. Beginning with the basic terms and concepts, the instructor will lead participants through lectures and multimedia presentations of the power generation technologies and power delivery systems. Participants will learn about issues such as reliability, performance and potential bottlenecks or limits on the system that can impact trading. They will gain an understanding of key power marketing fundamentals such as pricing and scheduling. · Basic design, operation and components of electrical supply systems · The integrated electrical grid – generation, transmission and distribution · Constraints and limitations of Power supply – voltage regulation, supply quality, reliability and efficiency and economics · The environment, renewable energy and the electrical regulatory regimes · The smart grid: What does it mean? How will it improve electrical supply?
Who Should Attend?
This course is targeted for non-technical persons needing to increase their understanding of the power system, system operations and the power market, including: · Financiers · Power traders · Power project developers · Support professionals in non-technical functions · Professionals in other energy industries. · Electric utility personnel who are new or have new job responsibilities.
Course Outline:
Day 1: Power System Overview
Basics of Power System Protection
Types of Faults and Short Circuit Current Calculations
Day 2: System Earthing and Earth Fault Current
Fuses and Circuit Breakers
Instrument Transformers
Relays and Auxiliary Power Equipment
Protection Grading and Relay Coordination
Protection of Feeders and Lines
Protection of Transformers
Course Methodology:
A variety of methodologies will be used during the course that includes: · (30%) Based on Case Studies · (30%) Techniques · (30%) Role Play · (10%) Concepts · Pre-test and Post-test · Variety of Learning Methods · Lectures · Case Studies and Self Questionaires · Group Work · Discussion · Presentation
Course Fees:
This rate includes participant’s manual, Hand-Outs, buffet lunch, coffee/tea on arrival, morning & afternoon of each day. Course Timings:
Daily Course Timings: 08:00 - 08:20 Morning Coffee / Tea 08:20 - 10:00 First Session 10:00 - 10:20 Coffee / Tea / Snacks 10:20 - 12:20 Second Session 12:20 - 13:30 Lunch Break & Prayer Break 13:30 - 15:00 Last Session |
|||||||||||||||||||||||||||
| COURSE OBJECTIVE | |||||||||||||||||||||||||||
| 0 | |||||||||||||||||||||||||||
| COURSE OUTLINE | |||||||||||||||||||||||||||
| 0 | |||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||
| EMAIL: nooraldeen@ictd.ae website: www.ictd.ae | |||||||||||||||||||||||||||