| Circuit Breakers Maintenance and Troubleshooting | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| COURSE DESCRIPTION | |||||||||||||||||||||||||||
Course Introduction:
This course is designed to update participants with the latest development of Circuit Breakers and to present some of the more common and updated aspects of low, medium and high voltage switchgear maintenance. It must be understood that there is an incredible variety of equipment used on low, medium and high voltage switchgear today. Circuit Breakers play an important role in the distribution and control of electrical power in manufacturing or power plant and in a utility distribution system. Negligent maintenance practices can lead to power system inefficiency and loss of system reliability.
An older plant may have switchgear that was built in the forties in the older areas and modern switchgear in other areas as the plant was upgraded. This course will present maintenance problems to the maintenance manager and technician. Newer plants will probably have modern equipment of a limited variety and manufacture. It is these similarities that will be covered in the course.
Course Objectives:
Upon successful completion of this course, the delegates will be able to:
Who Should Attend?
This course is applicable to engineers and other technical staff who need a sound understanding of Low, Medium and High Voltage Circuit Breaker inspection, maintenance, design, repair and troubleshooting.
Course Outline:
Day 1: · Introduction o Voltage Convention o Fundamentals of Circuit Breakers o Types of Breakers, Construction o Ratings, Tripping Characteristics
· Switchgear in a Network Context o Single Line o Utilization
· Introduction o Voltage Convention o Fundamentals of Circuit Breakers o Types of Breakers, Construction
· Switchgear in Historical Perspective o Oil Circuit Breakers o Air Blast CB o SF6 and Vacuum CB o Operating Mechanisms
Day 2: · Switchgear Details o Rating Ur, Ik, Ip, Va o Degree of Protection o Service Conditions o Ancillary Equipment
· Switchgear Asset Management o Equipment Register o CBM and RCM Process o Switchgear Diagnostic Techniques o Tripping Devices & Maintenance and Testing
Day 3: · Circuit Breaker Diagnostic Techniques o Diagnostic Techniques
· Switchgear Vital Equipment o Batteries Condition and Monitoring o Discussions
· Substation Maintenance Techniques o Description o Structures o Fuses, Arresters, Switches o Substation Compound o Switchgear Maintenance Practices
Day 4: · Substation Maintenance Techniques (cont’d) o Metal Clad Switchgear o Maintenance Details o Metal Clad Switchgear Maintenance Details o Maintenance & Repair Fundamentals o Maintenance & Repair Procedures
Day 5: · Maintenance Work Orders o Maintenance & Repair Procedures (cont’d) o Process Development o Procedures o Problems Encounters o Samples, Discussions
Course Methodology:
A variety of methodologies will be used during the course that includes:
Course Fees:
This rate includes participant’s manual, Hand-Outs, buffet lunch, coffee/tea on arrival, morning & afternoon of each day.
Course Timings:
Daily Course Timings: 08:00 - 08:20 Morning Coffee / Tea 08:20 - 10:00 First Session 10:00 - 10:20 Coffee / Tea / Snacks 10:20 - 12:20 Second Session 12:20 - 13:30 Lunch Break & Prayer Break 13:30 - 15:00 Last Session
|
|||||||||||||||||||||||||||
| COURSE OBJECTIVE | |||||||||||||||||||||||||||
| 0 | |||||||||||||||||||||||||||
| COURSE OUTLINE | |||||||||||||||||||||||||||
| 0 | |||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||
| EMAIL: nooraldeen@ictd.ae website: www.ictd.ae | |||||||||||||||||||||||||||